Visit
Official Website

Hexo Industries (M) Sdn Bhd
1-2-9, i-Avenue, Medan Kampung Relau 1, 11900 Bayan Lepas, Penang, Malaysia.
+6011-6528 1088
+604-611 1186
+6012-954 1088
+6012-558 2052
  +60129541088

Selangor Branch
Jalan Putra Bistari 2/5J, 47610 Subang Jaya, Selangor, Malaysia

Indonesia Branch
Jababeka Bizpark, Blok D/16, Jababeka Innovation Center, Pintu 6, Blok D/16, Cikarang, Bekasi, Jawa Barat 60292, Indonesia.

Singapore Branch
SpectrumSense Solutions
1 Scotts Road, #24-10 Shaw Centre, Singapore 228208.

Saluki S5104 Series Radio Communications Test Set (300kHz - 1.05GHz / 3GHz)

Previous 6 / 8 Next


The Saluki S5104 Series Radio Communications Test Set, which is a multifunctional and portable model based on software radio architecture and integrates plentiful functions. Wide applications of the tester cover R&D, production, verification, maintenance and repair, and testing on radio communication equipment.

 

Key Features

Multiple RF testing function

Analog standard communicaiton testing

Auto signal testing and auto signal software

Build-in attenuator with high power

Optional frequency-hopping testing

Optional dual-channel oscilloscope

Optional digital standard communicaiton testing
 

Detailed
 
 
 

 

S5104 Series Radio Communications Test Set, which is a multifunctional and portable model based on software radio architecture, integrates plentiful functions, like frequency-hopping signal generation and analysis, vector signal generation and demodulation analysis, analog modulation signal generation and demodulation analysis, audio signal generation and analysis, audio oscilloscope, automatic testing and so on. The tester is capable of major performance testes on transmit and receiving of radio communication equipment, measurement and analysis on feature parameters of RF, modulation, audio, and digit etc. Wide applications of the tester cover R&D, production, verification, maintenance and repair, and testing on radio communication equipment, including short-wave/ultra short-wave radio stations, data link systems, communication and surveillance satellites, radio relay equipment. Military mobile carriers with radio communication terminals like communication vehicles, surveillance vehicles, vessels and ships, as well as external field tests can use this tester conveniently.

 

 
Main Functions

Auto Testing Functions of Radio Communication Equipment

S5104 series radio communications tester can create and edit models, parameters and qualified specification limits of DUT. Choose your DUT and connect testing cable, the comprehensive tester will automatically conduct the testing. It controls transmit and receiving of the DUT by PTT. When the DUT needs setup or the cable needs being changed, the tester will automatically halt the testing and indicate further operation. The testing goes on after the operation is finished. Qualified and unqualified items will be listed directly. Other functions, like storage, viewing, comparison and remote readout, are also available.

Auto testing function

 

 

Transmitter Testing

S5104 series radio communications tester can conduct simultaneous tests on various performance specifications of transmitters, like signal power, frequency error, signal modulation characteristics, demodulation audio, and so on. Audio signals of transmitters can be provided and single/double tones are available for your choice. It can simulate pilot signals. 

Transmitter testing

 

Receiver Testing

S5104 series radio communications tester is able to send out FM, AM and SSB RF signals; analyze audio demodulation of the receiver; measures accurately audio frequency, voltage, distortion degree, SINAD and SNR.

Receiver testing

 

Function As RF Signal Generator

Analog modulation of FM, AM, SSB etc and digital modulation of BPSK, QPSK, 8PSK, GMSK,16QAM and so on can all be output. The max. symbol rate of digital modulation is 5MHz. The tester upholds generation of 60MHz transient bandwidth frequency-hopping signals. 

RF signal generator

 

RF Receiving And Demodulation

S5104 series radio communications tester is capable of demodulation and analysis of analog modulation like FM, AM, SSB etc and that of digital modulation signals including BPSK, QPSK, 8PSK, GMSK and 16QAM. Demodulation parameters and waveforms can be output. The max. demodulation bandwidth of analog modulation signals reaches 300kHz and the max. symbol rate of digital modulation and signal demodulation is 5MHz. Narrow band power measurement is available.

RF receiving and demodulation

 

Sweep Spectrum Analysis

S5104 series radio communications tester has wide frequency band, high resolution, high sensitivity, big dynamic range and other characteristics. 

Sweep spectrum analysis

 

Frequency-hopping Signal Analysis

The max. transient analysis bandwidth of frequency-hopping signals is 60MHz. The display types are three-dimensional spectrum graph, time-frequency graph and time-amplitude graph. The tester can capture, store and analyze frequency-hopping signals. You can view spectrum and modulation domain graphs at any time. When modulation domain measurement is in progress, it is capable of accumulation and display of frequency points within any timeframes. Frequency-hopping points can be observed directly. Pulse signals and transient signals can also be measured.

Frequency-hopping signal analysis

 

Audio Signal Generation

Single and double tones are available for your choice. The max. output level reaches 7Vrms. 

Audio signal generation

 

Audio Signal Analysis

Audio filter is optional. The max. input level is up to 30Vrms. The tester supports measurements on frequency, level, distortion degree, SINAD and SNR, as well as audio waveform display.

Audio signal analysis

 

Simultaneous Operation on Multiple Windows

Support simultaneous operation of 4 windows at most, each window can be enlarged individually.

Simultaneous operation on multiple windows

 

Typical Applications

S5104 series radio communications test set is extensively employed due to the powerful functions and performances, which is used for R&D, repair, maintenance and testing of communication equipment. 

Typical applications

 

 
Technical Specifications
RF Signal Generation
Frequency Range S5104B: 1MHz - 1.05GHz
S5104C: 1MHz - 3GHz
Frequency Resolution 1Hz
Output Level Range

GEN: -120dBm to +5dBm(max. modulation 0dBm)

T/R interface: -130dBm to -35dBm

Level Resolution 0.1dB
Level Accuracy

±1.5dB(>-110dBm), ±2.0dB(<-110dBm)

SSB Phase Noise f<=1.05GHz: -93dBc/Hz @20kHz
f>1.05GHz: -90dBc/Hz @20kHz
Harmonic

Better than -25dBc (>1MHz, <0dBm)

Non-harmonic

Better than -35dBc (>1MHz, +5dBm output)

Internal Analog Modulation Source

Sine, square wave, triangle, saw-tooth, dual-tone (analog pilot)

Broadband Power Measurement
Frequency Range S5104B: 400kHz - 1.05GHz
S5104C: 400kHz - 3GHz
Measurement Range

ANT interface: 0.1mW - 100mW

T/R interface: 100mW - 150W
Measurement Accuracy

15% (<=120W, CW or frequency modulation)

Narrow Band Power Measurement
Frequency Range S5104B: 300kHz - 1.05GHz (low frequency depends on small IF bandwidth)
S5104C: 300kHz - 3GHz (low frequency depends on small IF bandwidth)
Measurement Range

ANT interface: +10dBm to -80dBm

T/R interface: +51dBm to -40dBm
Measurement Accuracy

±2dB 

Receiving Bandwidth

6.25, 8.33, 10, 12.5, 25, 30, 100, 300kHz

Frequency Error Meter
Frequency Range S5104B: 300kHz - 1.05GHz (low frequency depends on small IF bandwidth)
S5104C: 300kHz - 3GHz (low frequency depends on small IF bandwidth)
Accuracy

Frequency standards ±1Hz

Audio Signal Generation
Waveform

 Sine, square wave, triangle, saw-tooth 

Signal Type

Single-tone, dual-tone

Frequency

20Hz - 20kHz (sine),

20Hz - 4kHz (square wave, triangle, saw-tooth)

Frequency Resolution

0.1Hz
Level Range

1mV - 7Vrms (10kΩ  load)

Level Accuracy

±5% (10kΩ load >=10mVrms)

Audio Signal Analysis
Input Impedance

150Ω, 600Ω, high impedance

Max. input Level

30Vrms (high impedance)

Audio Filter Low-pass: 300Hz, 5kHz, 15kHz, 20kHz
Band-pass: 0.3-3.4kHz, 0.3-5kHz, 0.3-15kHz, 0.3-20kHz
Sweep Spectrum Analyzer
Frequency Range S5104B: 100kHz - 1.05GHz
S5104C: 100kHz - 3GHz
Sweep Width

0Hz - whole frequency bands

Level Precision

±1.5dB

Min. DANL ANT interface: better than -125dBm
T/R interface: better than -75dBm
Resolution Bandwidth

30Hz - 3MHz (1-3 stepping)

Demodulation And Analysis oAnalog Modulation Signals

Frequency Range S5104B: 300kHz - 1.05GHz (low frequency depends on small IF bandwidth)
S5104C: 300kHz - 3GHz (low frequency depends on small IF bandwidth)
Signal Format

FM, AM, SSB

Demodulation

6.25, 8.33, 10, 12.5, 25, 30, 100, 300kHz

Demodulation Audio Filter Low-pass: 300Hz, 5kHz, 15kHz, 20kHz
Band-pass: 0.3-3.4kHz, 0.3-5kHz, 0.3-15kHz, 0.3-20kHz
Frequency Range of Demodulation Counter 20Hz - 20kHz
Demodulation Counter Resolution 0.1Hz
Sensitivity

<-100dBm (10dB SINAD, ANT interface)

Demodulation And Analysis of Vector Signals (Option)
Frequency Range S5104B: 300kHz - 1.05GHz (low frequency depends on small IF bandwidth)
S5104C: 300kHz - 3GHz (low frequency depends on small IF bandwidth)
Signal Format

GMSK, BPSK, QPSK, 8PSK, 16QAM

Demodulation Bandwidth 10kHz - 10MHz
Max. Symbol Rate 5MHz
Frequency-hopping Signal Analysis (option)
Filter

RC, RRC, GAUSS

Transient Bandwidth

60MHz, 30MHz, 15MHz, 7.5MHz, 3.75MHz, 1.875MHz

Capture Storage Depth 

8GB
Analysis Domain

Time-frequency (modulation domain), time-amplitude, time-spectrum (waterfall chart), spectrum at random time

Min. Time Resolution 10ns
Dual-channel Oscilloscope
Frequency Range DC-4MHz
Vertical Scale

10mV - 10V/mark (1, 2, 5 stepping)

Horizontal Scale

1us - 1s/mark (1, 2, 5 stepping)

Coupling Type DC, AC
Input Impedance

1MΩ

Digital SequenceGeneration And Bit Error Rate  Measurement(option)
Digital Format

PN3, PN5, PN9, PN11

Baud Rate

300bps - 1Mbps (BPSK, GMSK, 2FSK, 2ASK)

Bit Error Rate Measurement Range 0.1 - 0.000001
Internal Time-base

Frequency: 10MHz; Aging rate: 1×10-7/year;Temperature stability: ±0.05ppm (0 - 50°C)

More specifications in the datasheet.

 

 
General Information
Dimensions (H×D)

426×222×180mm (without handles and auxiliaries)

Weight <= 12kg
Working Temperature

0°C to +50°C

Storage Temperature -40°C to +70°C
Power Supply

Internal AC: 220V±10%, frequency 50Hz±5%;

External DC: 24V±2V (16V is Acceptable);

Built-in and rechargeable battery: >=11000mAh (option)

Consumption <100W
Cooling Type

Internal air cooling

Interface

RF: GEN interface(TNC), T/R interface(type N), ANT interface(TNC)

BNC: audio input, audio output, oscilloscope input etc

Others: network port (support remote control), 26-core testing bus interface, USB-host interface etc.

 

Standard Package
No. Item Qty.
1 Main machine 1 PC
2 User manual 1 PC
3

Tri-core 220VAC power cord

1 PC
4

N-BNC adapter

1 PC
5

N-SMA adapter

1 PC
6

TNC-SMA adapter

1 PC

 

Options
Option No. Item
S5104-H01

Built-in lithium battery

S5104-S01

Software for vector signal generation and bit error rate measurement

S5104-S02

Software for vector signal demodulation and analysis

S5104-S03

Software for frequency-hopping signal generation

 

S5104-S04

Software for frequency-hopping signal analysis

S5104-S05

Software for dual-channel oscilloscope

 


Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   


Subscribe Newsletter