Leybold Leak Detectors / Sniffer

The leak detectors of the PHOENIX 4 series are multipurpose helium leak detectors for detection of lowest detectable local and integral leak rates. They are equally well suited to both service testing and series production.


*** Pls email us for more info. Sales@hexoind.com ***

PHOENIX Quadro

Part number: (Wet backing pump) 250000V02
Part number: (Dry backing pump) 250001V02
Leak rate: bis 5 x 10-12 mbar l/s




PHOENIX Magno

Part number: (Wet backing pump)
Part number: (Dry backing pump)
350000V02
350001V02
Leak rate: bis 5 x 10-12 mbar l/s






PHOENIX Vario

Part number: 250002V02
Leak rate: bis 5 x 10-12 mbar l/s


Ordering Information                                                 

                                                                                            High Voltage 230 V, 50 Hz                   Low Voltage 100 V, 50/60 Hz
                                                                                                         Part No.                                                   Part No.
 
Recommended backing pumps, electrically controlled
 
TRIVAC D 4 B                                                                                    112 45                                                    140 081
 
TRIVAC D 8 B                                                                                    112 55                                                    140 082
 
TRIVAC D 16 B                                                                                  112 65                                                           -
 
TRIVAC D 25 B                                                                                  112 75                                                           -
 
SOGEVAC SV 16 D                                                                          960 186V                                                960 186V
 
SOGEVAC SV 28 BI                                                                          960 277                                                   960 278
 
SOGEVAC SV 40 BI FC                                                                   960 364V                                                        -
 
SCROLLVAC 7 plus                                                                       141007V10                                             141007V10
 
SCROLLVAC 10 plus                                                                     141010V10                                             141010V10
 
SCROLLVAC 15 plus                                                                     141015V10                                             141015V10
 
SCROLLVAC 18 plus                                                                     141018V10                                             141018V10
 
Recommended backing pumps, separate electrical supply
 
ECODRY 40 plus                                                                           161040V01                                                       -
 
ECODRY 65 plus                                                                           161065V01                                                            -
 


 
                                                                    
                                                                                                                                                Accessories
                                                                                                                                                Part No.
 
Transport Case PHOENIX Quadro                                                                                          252004V02
Transport Case PHOENIX Magno                                                                                           352004V02
Transport Case PHOENIX Vario                                                                                              252024V02
Partial flow system 1)
         115 – 230 V, 50/60 Hz, without pump                                                                             140 20
AF 16-25 exhaust filter, for partial flow system                                                                        189 11
Search gas spray gun                                                                                                              165 55
PHOENIX IO Interface                                                                                                             252211V02
PHOENIX Bus Interface Profibus                                                                                            252212V02
PHOENIX Bus Interface ProfiNet                                                                                            252213V02
PHOENIX Bus Interface DeviceNet                                                                                         252214V02
PHOENIX Bus Interface EtherNet/IP                                                                                       252215V02
PHOENIX Vario connector plug                                                                                               252300V02
Cable for PHOENIX Interface modules – 0.5 m                                                                      252293V02
Cable for PHOENIX Interface modules – 2 m                                                                         252290V02
Cable for PHOENIX Interface modules – 5 m                                                                         252291V02
Cable for PHOENIX Interface modules – 10 m                                                                       252292V02
PHOENIX IO Adapter cable to L300i                                                                                      252400V02


Reasons for using our Helium Leak Detectors for Fine Leak Testing
Leak testing is crucial because, well, everything leaks! Here are the fundamental reasons for performing leak tests:
  1. Preventing Material Loss by Leakage Detecting and addressing leaks ensures that valuable materials are not lost due to escaping gases.
  2. Avoiding Contamination Leaks can introduce contaminants into a system, affecting product quality and reliability.
  3. Ensuring Product Performance and Reliability Leak-free products perform better and are more reliable, leading to satisfied customers.
  4. Reducing Liability Leaks can lead to safety hazards, environmental issues, and legal liabilities.
  5. Minimizing Production Output Loss System downtime caused by leaks can significantly impact production output.
All of these factors contribute to improved quality and reduced warranty costs.
 

Why Hexo Uses Helium as a Tracer Gas?
  • Helium’s Properties:
    • Helium, with a molecular weight of 4 atomic mass units (amu), is readily available worldwide.
    • Its low background noise makes it an excellent choice for leak detection applications.
    • Helium is non-toxic, non-flammable, inert, and not easily absorbed.
    • It allows for non-destructive testing (NDT).
Why Choose Hexo:
  • Variety of Helium Leak Detector Models: Hexo offers different models to suit your specific needs.
  • Pump Options: Dry pumps or oil pumps are available for both cleanroom and non-cleanroom environments.
  • Customizable Pumping Speed: Choose the pumping speed based on your process requirements.
  • Flexible Types: Hexo provides options with or without carts, as well as handheld detectors.
  • Suitable for Various Test Methods: Whether it’s spray vacuum or sniffing, Hexo detectors can handle different testing approaches.
  • Comprehensive Support: Accessories, spare parts, and calibration services are available from Malaysia factory. Our experienced team provides technical support and training after sales.
  • Rental Units: If needed, you can rent Hexo Helium Leak Detectors.
 
Hexo Helium Leak Detectors are available for sale in Malaysia, Indonesia, Philippines, Vietnam, Singapore, Thailand, and the South East Asia Region.
 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   


Subscribe Newsletter